Place of Origin: | China air-cooled water chillers |
Brand Name: | RS or OEM |
Certification: | CE for China air-cooled water chillers manufacturer |
Model Number: | RS-L25AL |
Minimum Order Quantity: | 1 set of air-cooled water chillers |
---|---|
Price: | contact us for air-cooled water chiller price |
Packaging Details: | standard export packing of industry air-cooled water chillers |
Delivery Time: | 15 days according to air-cooled water chiller production |
Payment Terms: | T/T, West Union,MoneyGram,L/C etc |
Supply Ability: | 500 sets of air-cooled water chillers according to China Manufacturer ability |
Product: | China Air-cooled Chillers Supplier, China Air-cooled Water Chillers Manufacturer, | Keyword: | China Industrial Chillers OEM Factory; China Industrial Chillers OEM Plant |
---|---|---|---|
Condition: | New -10℃ Low Temperature Air-cooled Chillers | Warranty: | One Year For -10℃ Low Temperature Air-cooled Chillers |
Item No.: RS-L25AL
25HP -10℃ Low Temperature Air-cooled Chillers/Buy air cool chiller/water chiller with chiller compressor in good quality
If you need the price of the Low Temperature Air-cooled Chillers, please do send an E-mail to: 15113320579@vip.126.com
Description of the air cooled low temperature chillers,
The air-cooled low temperature chillers use a single closed-loop design for pressurized refrigerant. All models are equipped with compressor and motor overload protection, phase shortage and reversal alarms, anti-freeze thermostat, pressure gauges etc. They feature excellent performance and a long lifespan. The series of working flow is based on the basic principle of heat exchange. It is applicable to the industry that requires flow of precisely controlled chilled water, and considered as indispensable equipment for modern industry.
Features of the air cooled low temperature chillers,
1.Selected world class famous compressor for low-temperature refrigeration
2.Environment-friendly refrigerant R407C,R134A,R410A,etc,no harm to the ozone field and provide excellent cooling effects.
3.Options for temperature range: chilled water between – 5℃-30℃(depending on production needs to adopt different system configurations)
4. According to different needs, optional for various of cooling medium (chilled water): ethylene glyco, clcohol, alcohol ternary mixture etc.; the evaporator designed as anti-corrosive and with calcium chloride water.
5. Designed for 24 hours non-stop working condition to provide continuous cold source for all kinds of production processes.
6. Cooling system can be built with cold water tank and circulating pump, no need for cooling tower and cooling water pumps-easy installation and maintenance.
7. Equipped with various safety devices, providing stable performance with low noise and long life; LCD control panel enables simple and easy operations with visions of working conditions.
Specification of the air-cooled low temperature chillers,
Model | Unit | RS-L3AL | RS-L5AL | RS-L8AL | RS-L10AL | |
Cooling Capacity | KW | 2.92 | 4.68 | 7.83 | 10.98 | |
Kcal/h | 2514 | 4023 | 6732 | 9440 | ||
Compressor | Input power | KW | 2.25 | 3.75 | 6 | 7.5 |
Ralated power | HP | 3 | 5 | 8 | 10 | |
Type | Hermetic Scroll (Piston Type) | |||||
Total Input Power | KW | 3.18 | 4.86 | 7.25 | 9.4 | |
Power | 3HP-380V/50HZ(200V/220V/415V/460V 50HZ/60HZ) | |||||
Evaporator | Type | Shell and Tube/Plate Heat Exchanger | ||||
Pipe diameter | inch | 1" | 1" | 1-1/2" | 1-1/2" | |
Chilled fluid flow | m3/h | 1.41 | 2.26 | 3.78 | 5.31 | |
Refrigerant | Type | R22(R404A/R507) | ||||
Control Method | Expansion Valve | |||||
Condenser | Type | Finned Copper Tube+Low Noise Orter Fan | ||||
Pump | Power | KW | 0.75 | 0.75 | 0.75 | 1.1 |
HP | 1 | 1 | 1 | 1.5 | ||
Distance | m | 20 | 20 | 20 | 20 | |
Safty Protection | High and low Pressure Protection,Over Load Protection,Over Temperature Protection,Phase Sequence Protection etc. | |||||
Dimensions (L*W*H) | Air Cooled | mm | 960*630* 1073 | 1280*630* 1118 | 1550*830* 1543 | 1550*830* 1543 |
Model | Unit | RS-L12AL | RS-L15AL | RS-L20AL | RS-L25AL | RS-L30AL | RS-L40AL | |
Cooling Capacity | KW | 13.59 | 16.47 | 21.96 | 23.4 | 27.18 | 34.2 | |
Kcal/h | 11684 | 14160 | 18881 | 20119 | 23369 | 29405 | ||
Compressor | Input power | KW | 9 | 11.25 | 15 | 18 | 22.5 | 30 |
Ralated power | HP | 12 | 15 | 20 | 25 | 30 | 40 | |
Type | Hermetic Scroll (Piston Type) | |||||||
Total Input Power | KW | 10.9 | 13.47 | 18.8 | 22.55 | 28.5 | 36 | |
Power | 3HP-380V/50HZ(200V/220V/415V/460V 50HZ/60HZ) | |||||||
Evaporator | Type | Shell and Tube/Plate Heat Exchanger | ||||||
Pipe diameter | inch | 2" | 2" | 2-1/2" | 2-1/2" | 2-1/2" | 3" | |
Chilled fluid flow | m3/h | 6.57 | 7.96 | 10.61 | 11.31 | 13.13 | 16.53 | |
Refrigerant | Type | R22(R404A/R507) | ||||||
Control Method | Expansion Valve | |||||||
Condenser | Type | Finned Copper Tube+Low Noise Orter Fan | ||||||
Pump | Power | KW | 1.1 | 1.5 | 2.2 | 2.2 | 4 | 4 |
HP | 1.5 | 2 | 3 | 3 | 5 | 5 | ||
Distance | m | 20 | 20 | 20 | 20 | 25 | 25 | |
Safty Protection | High and low Pressure Protection,Over Load Protection,Over Temperature Protection,Phase Sequence Protection etc. | |||||||
Dimensions (L*W*H) | Air Cooled | mm | 1550*830* 1543 | 1850*1000* 1640 | 2150*1000* 1820 | 2400*1150* 1840 | 2600*1150* 1940 | 2150*2000*1820 |
Note,
1. Cooling Capacity is calculated based on: inlet/outlet chilled fluid temperature:12 ℃/7 ℃, inlet/outlet cooling water temperature: 30 ℃/35 ℃.
2. Working condition: Chilled fluid temperature: from 5 ℃ to 35 ℃. Inlet/outlet chilled fluid Temperature difference: from 3 ℃ to 8 ℃ Cooling water temperature: from 18 ℃ to 37 ℃, Inlet/outlet cooling water Temperature difference: from 3.5 ℃ to 10 ℃.
We reserve the right to modify above information without prior notice.
Machine color--- blue or grey white and black, or others;
Machine brand--- factory brand, OEM brand or no brand;
We do OEM!
We do B2B, B2C!
RS Plastics Machinery Co.,LTD (Zhongshan·China) |
|||
Contact Person |
Mrs. Pearl Zhu |
Position |
Export Manager |
Mobile Phone |
0086-13590932590 |
|
263567704 |
Wechat APP |
zhhy18 |
Skype |
PEARL20128 |
E-mail-1 |
|||
E-mail-2 |
|||
Website |
For more choice, please click the following,
If you need the price of the Low Temperature Air-cooled Chillers, please do send an E-mail to: 15113320579@vip.126.com